The WidePIX photon-counting camera by ADVACAM directly collects data during measurement, offering multiple energy thresholds for material decomposition, clearer resolution, and higher contrast images. This allows you to use as low or high flux as you need and uncover inner structures without the image getting too dark or too bright. All you need is a device with open implementation, an ethernet cable and water cooling.
Upgrade your CT machine and detect cracks, porosity, delamination, and other defects more effectively. Inspect critical areas such as welds or multimaterial joints in more detail.
Watch a story how researchers at the CT Research Group of the University of Applied Sciences Upper Austria have now showcased an industrial RX Solutions CT, combined with our WidePIX MPX3 camera. Apart from research projects, they also offer custom inspection of small samples for the public.
Review the samples mentioned in the video bellow:

X-ray voltage | 100 kVp |
X-ray current | 0.15 mA |
Detector exposure time | 0.2 s |
Detector energy threshold | 10.3 keV |
Source-object distance | 150 mm |
Object-detector distance | 100 mm |
Voxel size full foot | 200 𝜇m |
Voxel size implant scan | 170 𝜇m |

X-ray voltage | 100 kVp |
X-ray current | 0.15 mA |
Detector exposure time | 0.2 s |
Detector energy threshold | 10.3 keV |
Source-object distance | 180 mm |
Object-detector distance | 80 mm |
Voxel size | 100 𝜇m |

X-ray voltage | 100 kVp |
X-ray current | 0.15 mA |
Detector exposure time | 0.1 s |
Detector energy threshold | 10.3 keV |
Source-object distance | 130 mm |
Object-detector distance | 130 mm |
Voxel size | 70 𝜇m |

X-ray voltage | 100 kVp |
X-ray current | 0.15 mA |
Detector exposure time | 0.3-3.5 s |
Detector energy threshold | 5 – 30 keV, step 5 keV |
Source-object distance | 150 mm |
Object-detector distance | 100 mm |
Voxel size | 200 𝜇m |
X-ray voltage | 100 kVp |
X-ray current | 0.15 mA |
Detector exposure time | 1-5 s |
Detector energy threshold | 5 – 30 keV, step 5 keV |
Source-object distance | 240 mm |
Object-detector distance | 60 mm |
Our detectors offer a variety of imaging methods, such as material-sensitive spectral scan, planar imagig, 3D imaging, tomosynthesis, backscattering and many combinations of these. Thanks to time-delay integration of te WidePIX detectors, even large samples can be scanned without the need to dismantle or cut them.
For samples too large to fit into a standard industrial CT, consider using robotic arms. Their flexibility and portability offers a solution for practically any size and shape of objects.